Determining the Number of Safety Mats Controlled by a Control Unit

The maximum number of safety mats used with one control unit depends on the mat surface
coating. See below.
Aluminum (metal)
Nitrile (rubber)
If the number of mats necessary to cover an area exceeds these quantities, use more than
one control unit.

Area Controlled by Several Safety Mats Run by Several Control Units

When the total surface to be covered is larger than the maximum recommended surface per
control unit, use several control units. See figure 2-17. Refer to the Connections and Setup
section of the manual for proper interface to the machine stop circuitry.
Figure 2-17 Two Control Unit Area Control
26 Honeywell • PK 107007-01 EN FR26 GLO 0298 Printed in France
Up to 4 mats with a standard size of up to 6 m
Up to 5 mats with a standard size of up to 7.5 m
SAFETY MAT
PLANCHER DE SECURITE
SICHERHEITS-SCHALTMATTE
TEST
Control
Output status
Machine operation enabled
Machine operation disabled
Etat de la sortie
Marche de la machine autorisée
Marche de la machine interdite
Ausgangsstatus
Maschinenbetrieb-Freigabe
Maschinenbetrieb gesperrt
Sensing threshold
Normal
Call for Maintenance
Seuil de détection
Normal
Appeler la maintenance
Empfangspegel
Normal
Den Wartungsdienst anrufen
Test mode
Normal operation
Device in test condition
TEST
Test
Fonctionnement normal
Appareil en test
Test
Normalbetrieb
Gerät im Tesbetrieb
unit A
Power supply
Power off
Power on
Alimentation
Hors tension
Sous tension
Stromversorgung
Ohne Spannung
Unter Spannung
Light off
Light on
Flickering light
Lumière éteinte
Lumière allumée
Lumière clignotante
Licht aus
Licht ein
Blinkendes Licht
FF-SM
TYPE
N
(F) 38240 Meylan
S
V
T
Response time
P
F
IP
S
Imax/Vmax
NEMA
EC type examination certificate delivered by
INRS
Attestation d'examen CE de type délivrée par
EG Baumusterprüfbescheinigung von
Type 4 ESPE
pr EN 1760
pr EN 954- 1
Connecting
box A
Connecting
box B
SAFETY MAT
PLANCHER DE SECURITE
SICHERHEITS-SCHALTMATTE
TEST
Control
Output status
Machine operation enabled
Machine operation disabled
Etat de la sortie
Marche de la machine autorisée
Marche de la machine interdite
Ausgangsstatus
Maschinenbetrieb-Freigabe
Maschinenbetrieb gesperrt
Sensing threshold
Normal
Call for Maintenance
Seuil de détection
Normal
Appeler la maintenance
Empfangspegel
Normal
Den Wartungsdienst anrufen
Test mode
Normal operation
Device in test condition
unit B
TEST
Test
Fonctionnement normal
Appareil en test
Test
Normalbetrieb
Gerät im Tesbetrieb
Power supply
Power off
Power on
Alimentation
Hors tension
Sous tension
Stromversorgung
Ohne Spannung
Unter Spannung
Light off
Light on
Flickering light
Licht aus
Lumière éteinte
Lumière allumée
Licht ein
Lumière clignotante
Blinkendes Licht
FF-SM
TYPE
N
(F) 38240 Meylan
S
V
T
Response time
P
F
IP
Imax/Vmax
S
NEMA
EC type examination certificate delivered by
INRS
Attestation d'examen CE de type délivrée par
EG Baumusterprüfbescheinigung von
Type 4 ESPE
pr EN 954- 1
pr EN 1760
Mat nb 1
Mat nb 2
FF-SM Series Installation Manual
2
(65 ft
2
(81 ft
4
3
Dangerous
!
Machine Area
1
2
Mat nb5
cable
extension
For application help: see Warranty Information
2
) per control unit.
2
) per control unit.
6
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sya30 seriesSya60 series

Table of Contents