Honeywell SYA14 Series Manual page 121

Safety light curtains
Table of Contents

Advertisement

ELECTRICAL SHOCK
Properly ground FF-SB Series light curtain housing by connecting earth ground through the
connector. Vibration dampeners electrically isolate FF-SB light curtain housing from mounting
surface.
Failure to comply with these instructions could result in death or serious injury.
LIGHT CURTAIN DAMAGE
Mount FF-SB Series light curtains with vibration dampening to prevent damage to emitter and
receiver units.
Failure to comply with these instructions may result in product damage.
To mount one complete light curtain system, use two mounting bracket sets, one for the
emitter and another for the receiver. The emitter and receiver units may require different types
of mounting brackets based on application requirements. Order mounting accessories (FF-
SBZS8000) if the light curtain system is mounted directly to the machine, custom brackets are
used, or replacement mounting accessories are needed.
T-slot Mounting System
The FF-SB Series T-slot mounting design allows bracket placement anywhere along the back
of the light curtain housing (see figure 2-14). The two parallel T-slots are designed to fit the
head of an M6-25 bolt.
Figure 2-14 T-slots with Rotatable Mounting Bracket
Mounting Accessory Set
The mounting accessory set (FF-SBZS8000) may be used with custom brackets. The
accessory set contains the following hardware:
Mounting Accessory Set FF-SBZS8000
Mounting Hardware
M6.U Washer
H.M6 Nut
H.M6-25 Bolt
Onduflex ∅6 Washer
Rubber Vibration Damper (603 155.002)
Metal Hub (604 649.001)
40 Honeywell • MICRO SWITCH Sensing and Control
FF-SB Series Installation Manual
Quantity
8
8
8
8
8
8
For application help: call 1-800-537-6945