Diagonal and Right-Angle Mounting
IMPROPER INSTALLATION OF FF-SB SERIES LIGHT CURTAIN
To prevent operating personnel from access to danger zone, install hard guard or right-angle
mounting if distance between danger zone and closest light beam is greater than 70
millimeters (2.8 in.).
Failure to comply with these instructions could result in death or serious injury.
For point-of-operation guarding, the safety light curtain(s) and any hard guarding must be
installed so that no person can stand between the light curtain and the danger zone without
being detected.
mounting of the light curtain (see figure 2-12), or additional light curtains mounted at right
angles to each other (see figure 2-13).
Figure 2-12 Diagonal Mounting
A right-angle mounting arrangement may be used if the altered resolution at the joint is
acceptable to the local regulatory agency. If right-angle mounting is used, the units must be
mounted so the synchronization beams are as far apart as possible (see figure 2-13). The
emitters and receivers units should be mounted with opposite orientations to prevent mutual
interference or cross-talk.
Figure 2-13 Right-Angle Mounting

Mounting Hardware

FF-SB Series light curtains are designed with an easy to use T-slot mounting system. Three
styles of mounting brackets are available. Each style bracket includes the necessary mounting
accessories (bolts, nuts, washers, and vibration dampeners) to mount one emitter or one
receiver unit.
For application help: call 1-800-537-6945
Installation may require additional hard guarding, horizontal or diagonal
Elevation View
Honeywell • MICRO SWITCH Sensing and Control 39