Figure 4-2 Emitter and Receiver LEDs
Emitter LEDs
Supply voltage
LED
E1
E2
R1
R2
R3
R4
Test Plug Construction
Emitter Female Plug Connector
Using Female Plug Connector FF-
SBZ1721137, connect pins A4 and A5 to
supply voltage and the ground pin to earth
ground.
Emitter Board Visual Test
1. Clean the front lens window of the emitter.
2. Place your eye against the emitter front lens window and observe the presence of a low
energy red light (a spot) in the middle of each beam (except synchronization).
3. If you can observe the presence of this red light, the emitter is working correctly. If you
cannot, replace the faulty emitter board.
58 Honeywell • MICRO SWITCH Sensing and Control
Marginal signal
Synchronization
beam
Clear sensing
field
Location
Emitter
Emitter
Receiver
Receiver
Receiver
Receiver
(see troubleshooting flow diagram, sheet 1 of 2)
FF-SBZ1721137
(see troubleshooting flow diagram, sheet 2 of 2)
FF-SB Series Installation Manual
Receiver LEDs
Color
Function
Yellow
Supply voltage on
Yellow
Synchronization beam detection
Red
Marginal signal detection
Red
Interrupted sensing field
Green
Clear sensing field
Yellow
Illuminated=test,
Flickering=restart required
Receiver Female Plug Connector
FF-SBZ1721202
Using a Female Plug Connector FF-
SBZ1721202, connect pins A4 and A5 to
supply voltage and the ground pin to earth
ground. Also jumper the following pins: C4,
C5, B3 and C3.
For application help: call 1-800-537-6945
Interrupted
sensing field