50FY Series
SPECIFICATIONS
FYQLA1-140R-3 Logic Amplifier
Input voltage
100 - 128 VAC, 50-60 Hz
Power dissipation
3.0 VA max.
Temperature range
-40 to +70°C (-40 to +158°F)
Output relay
Contact rating: 5 A @ 120 VAC
Action: single pole, single
throw, N.O.; Positive guided
safety relay; Dual relays
connected in series, single
output; Electrical life: 100,000
operations @ full load
*Sealing
Logic amplifier must be in a
NEMA sealed enclosure.
50FY41 Hall Effect Sensor
Voltage
10 - 12 VDC
Load current
0.50 mA max.
(internally restricted)
Current consumption
20 mA
Temperature range
-40 to +85°C (-40 to +185°F)
Sealing
NEMA 1, 3, 4, 6P, 12, 13 and
**washdown test
Units are resistant to repeated
washdown with caustic solution,
steam cleaning, food, juices
and pulp.
*Sealing: Enclosures are based on the broad definitions
outlined in NEMA standards. Therefore, the customer
must determine that a particular enclosure is adequate
when exposed to a specific condition in an application.
Except as otherwise noted, all references to products
relative to NEMA enclosure types are based on MICRO
SWITCH evaluation only.
**Washdown Test: MICRO SWITCH Test Specifications
060.167, Issue 2, Paragraph 4.9 is a test specification for
a high pressure (1200 psi), high temperature (140 °F)
chemical washdown. This test simulates cleaning
procedures used by food and beverage processing plants
which are more severe than standard NEMA 4 hosedown.
A description of the washdown specification is available
upon request.
This product conforms to the technical requirements
of EN60730-2-1 as applicable to an Electronic
Incorporated (for Class I equipment) sensing control
with Type 2 and 2B action for continuous operation
in normal pollution standards.
Honeywell • MICRO SWITCH Sensing and Control 5
PK 80391
ISSUE 3