Transport And Storage; Ff-Se Replacement Procedure - Honeywell SYA14 Series Manual

Safety light curtains
Table of Contents

Advertisement

6.5 Transport and storage

Please observe the following transport instructions:
• Remove all plugs to prevent damage to the cables.
• Fix rotating parts with an adhesive band to protect the lens from being scratched.
• Avoid any mechanical stress on the rotating parts.
• Whenever possible use the original shipping package .
• Clearly, indicate on the packaging that the product is «fragile».
Please observe the following storage instructions:
• Ensure the sensor is dry before putting it into storage. Condensation will damage the optical parts.
• Do not store the sensor in an air-tight container to prevent trapping any moisture.
Failure to comply with this instruction may result in product damage.
• Storage humidity : 5 to 85% (without condensation).
• Storage temperature : -20 to +70° C (-4 to 158 °F).

6.6 FF-SE replacement procedure

During initial sensor programming (alarm zone, safety zone, password, restart delay) and when exiting the main menu,
save the program on a disk using a file name relating to the installation (do not use the serial number).
For example : POST23.PRM or AGV2B.PRM.
If a replacement sensor is required (damaged sensor, maintenance, break down...) do the following :
1)
Obtain a new sensor, a PC and a disk with the saved installation information.
2)
Ensure the machinery is in a safe state (stopped, power removed...)
3)
Shut down the power supply, disconnect the sensor power cable, remove the mounting hardware and
sensor.
4)
Store the sensor in the special shipping container.
5)
Install the replacement sensor using mounting hardware :
Ensure the sensor is in the same location as the previous sensor in relation to the reference target. Also,
ensure the optical head is clean and moves freely.
6)
Connect the replacement sensor to the « 24 Vdc/signal » cable plug. Ensure the cable plug is hand tight.
7)
Power up the sensor.
8)
Observe the replacement sensor starts up after an initial self-checking period about 10 seconds. The safety
(red) and warning (yellow) LED's should light up (unless the sensor is positioned in an open area of more
than 10 m (32.8 in)), because the maximum safety and alarm zone parameters are factory pre-programmed
(radius of 6 m (19.68 in) and 10 m (32.8 in)).
9)
Connect RS232 cable to the sensor's "Interface connector".
41
107006-11 EN FR26 GLO 0300 Printed in Germany

Advertisement