Configuration - JUMO variTRON 300 Operating Manual

Automation system central processing unit
Hide thumbs Also See for variTRON 300:
Table of Contents

Advertisement

4.4.4

Configuration

The following sections are merely intended to provide an overview of the functions which are configured
under the respective tile.
The process of configuring the individual functions in the CPU (master) is described in detail in the "Con-
figuration" chapter in this document.
chapter 5 "Configuration", Page 69
The process of configuring the modules (controller, relay, analog IO units, digital IO units) is described
in the operating manual for the respective module.
chapter 1.8 "Available technical documentation", Page 18
Device manager
Here, device settings are configured (device language, start-up behavior, partition change), device des-
ignations are assigned, the time zone and time server are selected, and the date and time are manually
set. In addition, the customer-specific linearization is configured here ( as of system version 5).
System bus
The "Master" tile is where settings relating to the transfer of data via the system bus are configured.
NOTE!
The settings configured under "Master" influence the transfer of data via the system bus. Sub-optimal
settings here will disrupt or even interrupt the communication within the system. For this reason, these
parameters are only permitted to be modified by a service engineer from the device manufacturer (or by
someone acting on their instructions).
The modules connected via the system bus are each depicted by a separate tile, which takes the user
to the module configuration.
Data carrier management
Settings for the use of network drives are made here (available as of system version 7).
Ethernet
The Ethernet interface LAN1 and, if applicable, other Ethernet interfaces (LANx) are configured here.
Web server
The web server function is configured here.
Email
The settings for sending emails are configured here.
PLC configuration
Here, the units for absolute and relative temperature values are determined (for the PLC application),
the program generators are configured, and settings for the analog and digital variables (as of system
version 5) are made.
PLC parameters
If applicable, PLC parameters are defined here.
Programs
Programs (setpoint values, operating contacts) are created here using the program editor.
System status UI
The screensaver is configured here.