5 Configuration
5.4

Data carrier management

Network drives
Here up to 5 network drives are mounted under Linux (available as of system version 7).
Parameter
Name
Network path
File system
Additional mount
options
NOTE!
As of system version 7, access to the file system on USB storage media via CODESYS is also support-
ed.
74
Selection/data input
Enter text
Enter text
SMB/CIFS
Enter text
Description
Designation for the network drive
Examples: Drive1, Drive2
Network path of the drive
Examples: //Server/NetDrive, //Server/NetDrive2
Network file system
SMB/CIFS is supported up to and including ver-
sion 3.1.1. To use a specific version, it must be
specified as an additional mount option (vers=x.x).
Additional options for mounting the drive under Li-
nux
The options are to be entered separated by com-
mas.
Example (public drive, SMB/CIFS in version 1.0):
guest,user=,vers=1.0