16.9. Charge voltage setting table (Login=Expert)
This setting is made at the factory and only needs to be adjusted if a different type of battery is used.
Operating
Icon
steps
1
2
3
4
5
Mounting- and Operating Instruction Eaton LoadStar-S JSB 40071860396 March 2021 www.ceag.de
16.9. Charge voltage setting table (Login=Expert)
Function
Entries
Icon Menu
Actuate
Icon
Actuate
General setup
Icon Charger/Bat-
Actuate
tery setup
Icon Battery setup
Go to Icon Battery Settings and press
Icon Battery ca-
Enter the nominal capacity of the
pacity
battery at +20°C, 1.8V/Z and C10.
Number of blocks
Enter the number of battery blocks
per battery
Enter the float charge voltage per cell
Trickle charging
in mV.
Number of cells
Enter the number of cells per battery
per block
block.
43