39 LoadStar-S 12C4

39 LoadStar-S 12C4
The LoadStar-S 12C4 in IP21 (IP31 optional, IP54 on
request) version with individual cable entry in accordance
with EN 50171 is suitable for supplying up to 48 circuits
for safety and escape sign luminaires 230V / 216V AC/DC
in the power range up to 5.4KW. A distribution board for
mains and battery enables the connection of sub-stations
of type LoadStar-S US 7 and LoadStar-S SOU. The wiring
system with rounded mounting fields does without classic
cable ducts and, in combination with the natural ventilation
and the large ventilation slots of the mounted modules,
ensures a homogeneous control cabinet climate which has
been proven by heating tests in accordance with EN 61439-
1 under nominal load conditions. The clear, self-explanatory
internal modular field structure, taking contact protection
into account, rounds off the appearance.
The extensive catalogue of cabinet accessories such as
special locks, door hinges right/left, cable entries, bases in
various heights, IP31 retrofit kits and IP54 on request offers
the right solution for most customer-specific requirements
without long delivery times.
The colour touch display with automatic testing device and
individual luminaire monitoring with individual status and
name indication per luminaire in conjunction with system-
related ECG / LED supply module including monitoring
module without additional data line reports and records
the operating status of the external phase monitor modu-
les, the insulation monitoring device as well as the battery
strings and, if battery block monitoring technology is used,
the operating status of each individual battery block.
84
Mounting- and Operating Instruction Eaton LoadStar-S JSB 40071860396 March 2021 www.ceag.de
3
4
Cable entry from above.
Roof plate with IP X1 dripping water protection foil and
holes for:
28 x M16
49 x M20
4 x M32
The dripping water protection of the film is no longer gua-
ranteed after the cables have been inserted without the
appropriate cable gland.
5
1
2
ATTENTION!
6
3
4
Geprüft/
Erstellt/
2.9.19
Kufrej
issued
checked
Entstanden aus/
Ersatz für/
replacement for
developed from
Längen/ length
Radius/ radius
Winkel/ angle
E 100757
Werkstoff/ material
19.2.20
Kufrej
D
2.9.19
Kufrej
Stand/
Name/
Änderung/
Datum/
index
modification
date
name
Benennung/ designation
40071362100_nVent
nVent 11391-454
7
A
B
C
D
CTQ
Freim.-Toleranz/

Advertisement

Table of Contents
loading

Table of Contents