Display Bbu Design Parameters; Display Current Bbu Properties - LSI iBBU01 User Manual

Hide thumbs Also See for iBBU01:
Table of Contents

Advertisement

Table 3.3
Display BBU Capacity Information (Cont.)
Description
Displays BBU capacity information. The information displays in the following format:
BBU Capacity Info for controller: x
Relative State of Charge: xx%
Absolute State of Charge: xx%
Remaining Capacity: xx mAh
Full Charge Capacity: xx mAh
Run Time to Empty: xxx Min
Average Time to Empty: xxx Min
Average Time to Full: xxx Min
Cycle Count: xx
Max Error: xx%
3.1.2.4

Display BBU Design Parameters

Table 3.4
Display BBU Design Parameters
Convention
CmdTool -AdpBbuCmd -GetBbuDesignInfo –aN|-a0,1,2|-aALL
Description
Displays information about the BBU design parameters. The information displays in
the following formats:
BBU Design Info for controller: x
Date of Manufacture: mm/dd, yyyy
Design Capacity: xxx mAh
Design Voltage: mV
Serial Number: 0xhhhh
Pack Stat Configuration: 0xhhhh
Manufacture Name: XXXXXX(String)
Device Name: XXXXXX(String)
Device Chemistry: XXXXXX(String)
3.1.2.5

Display Current BBU Properties

Table 3.5
Display Current BBU Properties
Convention
CmdTool -AdpBbuCmd -GetBbuProperties –aN|-a0,1,2|-aALL
3-8
Use the command in
selected controller(s).
Use the command in
the selected controller(s).
Using the Battery Backup Units
Copyright © 2006-2009 by LSI Corporation. All rights reserved.
Table 3.4
to display BBU design parameters for the
Table 3.5
to display the current BBU properties for