to a RAID controller. The battery backup unit must be mounted inside
the chassis within 10 inches of the RAID controller.
Because server and workstation chassis vary from vendor to vendor,
there is no standard mounting option that is compatible with the various
system configurations. Therefore, the iBBU05 battery kit contains only
the battery and the cable, allowing VAR's and chassis manufacturers to
customize the location of the remote battery to provide the most flexibility
within various environments.
Follow these steps to install the iBBU05 remotely.
1. Ground yourself, and remove the iBBU05 from the package.
2. Use the three Phillips-head screws that are provided to secure the
iBBU05 to the motherboard or server chassis.
3. Insert the battery pack harness connector at the end of the 5-pin
cable into the J2 connector on the backside of the iBBU05.
4. Connect the J1 connector on the iBBU05 to the J10 battery backup
connector on the backside of the SAS 8888ELP RAID controller, as
shown in
Figure
Use the supplied 20-pin, 10-inch cable to connect to a controller.
There are black triangles on the connectors to help you install them
properly. Insert the cable connectors into the controller connector
and the iBBU connector so that the black triangles are aligned, as
shown in the example in
Installing the Battery Backup Units