Input TS Errors Pop-up Window
Clicking any of the Errors buttons in the Input Stream Status window displays a
corresponding pop-up, which indicates current conditions for that particular line item:

GigE MPTS Alarms and Traps

There are three alarms and traps associated with GigE MPTS redundancy and input
stream monitoring. These alarms and traps inform you whenever a threshold event, a
Primary to Secondary failover event, or a GigE input stream low bit rate event occurs.
The Threshold alarm is set to Critical whenever any Primary input stream falls below
the specified threshold percentage. The alarm clears when all Primary input streams
are above the threshold level. A trap is issued for the first threshold event.
The Primary Failover to Backup alarm is set to Critical whenever any Primary input
stream fails over to the backup (secondary) stream. The alarm clears when all
redundant pairs fallback to the Primary input stream. A trap is issued for the first
failover event.
Status • Reports
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
573408-001-a
B
249