7. Replace the appropriate I/O module (see Figure 3–11):
a. Disconnect all bus cables from the I/O module.
b. Remove the failed I/O module.
c. Install a replacement I/O module.
d. Reconnect all bus cables to the I/O module.
8. Press Enter/Return to resume device port activity and restart the "other
controller."
NOTE: A controller restart is indicated by the temporary cycling of the port LEDs and a
F
LASHING
IMPORTANT: If the "other controller" did not restart, press the controller reset button.
9. Enable failover and re-establish the dual-redundant configuration with one of the
following commands:
SET FAILOVER COPY=THIS_CONTROLLER
or
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem configuration from "this controller" to the
"other controller."
10. If desired, verify the failover configuration with the following command:
SHOW THIS_CONTROLLER FULL
11. Disconnect the PC or terminal from the controller maintenance port.
HSG80 Array Controller V8.7 Maintenance and Service Guide
reset button.
Replacement Procedures for BA370 Enclosure Elements
3–37
Need help?
Do you have a question about the StorageWorks HSG80 Array Controller V8.7 and is the answer not in the manual?
Questions and answers