IMPORTANT: If the controller did not restart, use the following steps:
a.
Press and hold the controller reset button.
b.
Reseat the controller program card.
c.
Release the reset button.
11. From the CLI prompt, display details about the configured controller using the
following command:
SHOW THIS_CONTROLLER FULL
12. Set the subsystem date and time using the following command:
SET THIS_CONTROLLER TIME=dd-mmm-yyyy:hh:mm:ss
13. Mount the logical units on the host.
14. If using a Windows NT or Windows 2000 platform, restart the server.
15. Disconnect the PC or terminal from the controller maintenance port.
Replacement Procedures for Controller and Cache
Modules in a Dual-Redundant Controller Configuration
Follow the instructions in this section to replace modules in a dual-redundant
controller configuration (see Figure 3–7).
HSG80 Array Controller V8.7 Maintenance and Service Guide
Replacement Procedures for BA370 Enclosure Elements
3–13
Need help?
Do you have a question about the StorageWorks HSG80 Array Controller V8.7 and is the answer not in the manual?