The following menu appears:
Select an option from the following list:
Code Load & Patch local program Main Menu
0: Exit
1: Enter Code LOAD local program
2: Enter Code PATCH local program
3: Enter EMU Code LOAD utility
Enter option number (0..3) [0] ?
3. Enter option 2. The following menu appears:
You have selected the Code Patch local program. This program is used to manage
software code patches. Select an option from the following list:
Type ^Y or ^C (then RETURN) at any time to abort Code Patch.
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ?
4. Enter option 3. The following menu appears:
The following patches are currently stored in the patch area:
Software Version - Patch number(s)
xxxx
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ?
5. Enter option 0.
6. For dual-redundant controller configurations, repeat step 1 through step 5 for the
second controller.
HSG80 Array Controller V8.7 Maintenance and Service Guide
xxxx
Upgrading the Subsystem
5–33