Download Print this page

VETRON 5000 Service Manual page 49

Hide thumbs Also See for 5000:

Advertisement

1
2
4
DISPLAY
»
DISTANCE BETWEEN HOOK AND NEEDLE
01
02
1
1
H
o k-
o
n
e
e
d e
l
03
d
i
s
t
a
n
c
e
setup
04
05
06
07
08
NOTICE:
After this adjustment the following adjustment step 03.12., 03.13. and 03.14.
must be performed (again).
09
NOTE:
At stitch length 0 the hook point should have a distance to the needle scarf of 0.1mm.
3
STEP
Activate the ADJUSTMENT WIZARD
(see 02.01. / Page 19).
»
Until chapter 11 appears on the display.
»
Confirm.
Loosen screws
,
and
1
2
Turn the screw
inwards to move the needle guard
5
Turn the machine until the hook point is positioned
in the middle of the needle (NEEDLE RISE POSITION).
Move the hook carrier
to get a distance
4
between hook point and needle scarf of 0.1mm.
Tighten screw
and
3
.
2
»
Confirm to proceed to the next step.
03. ADJUSTMENT
11. DISTANCE BETWEEN HOOK AND NEEDLE
DESCRIPTION
INFO: The pedal is blocked. While
turning by hand the display shows the
machine position in degrees. Stitch
length is set to 0mm.
.
3
6
VETRON 5000 - FLAT BED MACHINE - SERVICE MANUAL
5
6
away from the needle.
05/2019
47