MAINTENANCE WORK
LUBRICATION OF THE MACHINE HEAD
NOTICE:
By tilting the machine during power on, a safety switch automatically switches the machine into
BLOCKED MODE. This is noted on the display.
Lubrication of the machine head
NOTICE:
Please use only oil types recomended by VETRON or an equivalent oil with the following specification:
E.g.: Oil PP 20 DAB 10
(Viscosity 40° C: 15 mm
WARNING!
Oil can cause skin irratation. Avoid contact.
If on skin, wash e ected area thoroughly.
NOTICE:
The handling and disposal of mineral oils is subject to legal regulation.
Deliver used oil to an authorized collection point.
Protect your enviornment. Take care not to spill oil.
DESCRIPTION
01. Tilt the machine to the back.
The oil tank is located below the base plate.
02. If necessary, slightly pull out the oil plug
fill the tank up to the MAX marking
2
/s; Flashpoint: 150°)
05. MAINTENANCE
1
and
2
.
VETRON 5000 - FLAT BED MACHINE - SERVICE MANUAL
02. LUBRICATION
OPERATING HOURS
8