Read Module Version; Read Local Device Address; Set Shutdown Timing; Clear Link Key Table - Intermec 6820 Series User Manual

80-column printer
Hide thumbs Also See for 6820 Series:
Table of Contents

Advertisement

6820 Series 80-Column Printer User's Manual
In Modes L1 and L2, other devices are allowed to connect but only the
first device to connect is paired and bonded. Other devices are always re-
quired to supply a PIN code to complete the connection.
In Mode L3, only one device is allowed to connect. This device is paired
and bonded and needs to supply the PIN code only on the initial connec-
tion.
Example: "L3<CR>"
Note: Some of the Bluetooth user interfaces cannot supply a NULL string
as a PIN code. Use the S4 command to specify a PIN code that is not
NULL.

Read Module Version

Command
V0<CR>
Description
Displays the firmware build version currently running
Example
"V0<CR>"
Returns: "v1yyyymmddHHMM<CR>"
Note: This command responds with the requested data only not the "ACK<CR>"

Read Local Device Address

Command
V1<CR>
Description
Displays the local device address
Returns
"v1%xx%xx%xx%xx%xx%xx<CR>"
Note: This command responds with the requested data only not the ACK<CR>
Example: Sent: "V1<CR>"
Received: "v1%00%2C%C6%03%45%39"

Set Shutdown Timing

Command
T0<Time in Minutes><CR>
Description
"Time" – Integer value - 0 implies never expire the timer
Range
0–270 minutes
Default
120
Example
"T0120<CR>" This sets the shutdown timer to 120 minutes.

Clear Link Key Table

Command
B0<CLR><CR>
Description
Clear Pair or Bonding command cleans up all of the link key and
Bluetooth address combination PSKEYs.
Default
None
Example
"B0CLR<CR>" This clears all saved link keys.