Diagnostic Information (continued)
Field
ID
Length
Description
30
2
Temperature, minimum and maximum over last 50 re-
ports. Set A2D value.
2
Temperature, minimum and maximum over printer life.
Set A2D value.
1
Temperature error. Last A2D conversion below -10 or
above +60 Celsius recorded.
2
Page number at last temperature error.
2
Total number of temperature errors.
40
2
Total number of head-jams
1
0 = No Home detect switch error
1 = Home switch engagement error
0 = Seeking; 1 = Printing
0 = Left; 1 = Right
00 = Acceleration
01 = Constant speed
10 = Deceleration
00 = 250 PPS ( initialization)
01 = Low speed
10 = High speed
0
reserved
1
Acceleration or deceleration step motor value when jam
occurred
1
Ambient temperature when Head Jam occurred. Set A2D
value.
2
Form number where Head Jam occurred.
2
Carriage Position where Head Jam occurred.
6820 Series 80-Column Printer User's Manual
Chapter 7
Troubleshooting and Diagnostics
Stored as
2 bytes
2 bytes
1 byte
2 bytes
2 bytes
2 bytes binary
bit 0
bit 1
bit 2
bits 3-4
bits 5-6
bit 7
1 byte binary
1 byte
2 bytes binary
2 bytes binary in 1/720"
Total
Length
11 bytes
11 bytes
127