16.

Implementation Conditions

The following figures show implementation conditions of the R-IN32M4-CL3.
Open the aluminum dry pack
Infrared reflow (within 3 times)

Figure 16.1 Implementation Flow

・Maximum temperature (package surface temperature):
・Time of maximum temperature:
・Time over which the temperature is 217C or more:
・Time to reach preheating temperature (150 to 200C) :
・Maximum number of times to reflow:
・Safe-keeping restriction period after opening the dray pack:

Figure 16.2 Infrared Reflow Temperature Profile

R18UZ0074EJ0100
Dec 24, 2019
Storage period is
within 7 days*
Yes
200
°C
150
°C
60 to 120 s
(preheating)
No
Baking
(125°C, 24 to 72h)
*Storage conditions: 5 to 30°C temperature,
less than 70% humidity
250C or below
30 s or less
Within 150 s
60 to 120 s
3 times
Within 7 days
250
245
°C
217
°C
30 s max.
60 to 150 s
Time (s)