Implementation Conditions - Renesas R-IN32M4-CL2 User Manual

Board design edition
Hide thumbs Also See for R-IN32M4-CL2:
Table of Contents

Advertisement

R-IN32M4-CL2 User's Manual: Board design edition
18.

Implementation Conditions

The following figures show implementation conditions of the R-IN32M4-CL2.
Open the aluminum dry pack
Infrared reflow (within 3 times)
Figure 18.1
Implementation Flow
・Maximum temperature (package surface temperature)
・Time of maximum temperature
・Time over which the temperature is 217°C or more
・Time to reach preheating temperature (150 to 200°C)
・Maximum number of times to reflow
・Safe-keeping restriction period after opening the dray
pack
Figure 18.2
Infrared Reflow Temperature Profile
R18UZ0046EJ0200
Dec. 28, 2018
Storage period is
within 7 days*
Yes
217
200
°C
150
°C
60 to 120 s
(preheating)
No
Baking
(125°C, 24 to 72h)
*Storage conditions: 5 to 30°C temperature,
less than 70% humidity
: 250°C or below
: 30 s or less
: Within 150 s
: 60 to 120 s
: 3 times
: Within 7 days
250
245
°C
°C
30 s max.
60 to 150 s
Time (s)