For easy finding the information in the programming tables, the ADDRESSES are organized in 7 separate sections:
 The first digit of the ADDRESS structure describes:
0 - Programming the engineer and common system parameters;
1 - Programming the access codes in the system;
2 - Programming the zone parameters in the system;
3 - Programming the PGM outputs in the system;
4 - Programming the partitions in the system;
6 - Programming the parameters of the communication devices in the system;
7 - Programming the parameters of the peripheral devices in the system.
 The second and the third digit in the ADDRESS structure logically separate the unit number for every sec-
tion - for example 01, 02 and so on are zone numbers. The same principle is right for the sections for program-
ming the parameters of access codes, zones, PGM outputs, partitions, communication and peripheral devices
in the system.
 The forth digit in the ADDRESS structure is the number of a parameter for a specific system resurse.
Example for ADDRESS structure reading:
Section for zone
Besides the information for activating and deactivating of the system parameters, for some menus are shown and con-
crete examples for the status and indication of the LCD keyboards.
Basic sequence in operation when programming the Engineer menu:

Remote programming of CA62

To access a ProSTE software program system requires an ID number and a station ID number. After restoring the de-
fault parameters these numbers will be the same and are 1234. In order to provide access to the system from the central
station enter the correct number of the central station at ADDReSS 6901 (PC ID).
A 24-hour period automatically begins after default parameters are restored during which the UDL communication with
the system is enabled even when the "ring number" parameter is zeroed at ADDReSS 6904 (with set 0 number, the
UDL communication will starts after receiving of 7 rings). After the initial 24-hour period, the UDL communication with the
system will enabled only if the "ring number" parameter set at ADDReSS 6904 is different from zero.
If during the 24-hour period the system is power off (together the main power supply and the battery), at the next power
on the started already 24-hour period will be disabled and the UDL communication will be enabled only if the "ring
number" parameter set at ADDReSS 6904 is different from zero.
If during the 24-hour period the engineer enters the ADDReSS 6903 and exit it by pressing the eNt button (with confir-
mation), then the 24-hour time period and this case will be disabled.
Detailed working instructions for the ProSTE software program are provided in the built-in Help files. The connection
between the local computer and the CA62 control panel is via a specialized module (the module is not included in the
CA62 equipment and is sold as a separate product.)
The details listed in this manual apply to all parameters for remote system programming.

Programming of Default Configurations in the CA62 Alarm Control Panel

The system supports 2 separate default configurations with set parameters. Enter a number of default configuration
(0-3) at ADDReSS 1000 in the engineer programming menu - see item 1. User and Manager Codes Programming. At
SUPPLEMENT B are shown examples for using the default configurations in the system.
AtteNtIoN: With realizing full hardware reset, in the system automatically will be set the
default configuration 0 parameters!
The default configuration 0 parameters are described in details in Table 1 (SUPPLEMENT
A) and they are described in ADDReSSeS tables below.
Installation and Programming Manual - СА62 Alarm Control Panel
Zone number
programming
Parameter for
programming the
zone type
19