Electrical supply

The Novo free standing fire is supplied with a power cord (length 1500 mm) and a 3-pin plug. The
standard electrical connection passes through the rear panel. The power cord can be drawn back
inside the outer panel and brought into the fire from below if preferred. This is more likely with the
cabinet or plinth installations, especially if they are not installed close to the wall. If shifting the
position of the power cord, it is recommended that the rubber grommet is left in place to cover the
hole in the back panel.
The connection is either direct wired* or connected to a
dedicated 240 V, 10 A earthed power point. The electric
isolation switch must be accessible after the appliance
has been installed.
The heater must not be located immediately below a
socket outlet (potential fire hazard).
The power cord is not fire rated and should not come into
contact with the unit. If the power cord is damaged, it must
be replaced by a licensed tradesperson. This must be a
genuine replacement part available from Rinnai.
* Consult a qualified electrician if direct wiring is required as it must comply with AS/NZS 5601 and AS/NZS 3000 and
* Consult a qualified electrician if direct wiring is required as it must comply with AS/NZS 5601 and AS/NZS 3000 and
other relevant local regulations