Gas supply

Gas pipe sizing must consider the gas input to this appliance, as well as other gas appliances in
the premises. The gas supply termination is inside the heater, and enters from the lower left hand
side of the appliance.
Purging the gas supply
Foreign materials and debris such as swarf, filings etc. must be purged from the gas supply.
Failure to do so may cause damage to the control valve causing it to malfunction.
The use of rubber hose for any gas connection to a fixed appliance is NOT authorised by the
manufacturer.

Electrical supply

The Evolve has a 1.5 m power cord with a three pin
plug supplied. The power cord passes through a slot in
the back left hand corner of the appliance.
Rinnai recommend the unit be plugged into a
230 V, 10 A earthed power point. The power point
must not be above the heater. Alternatively the
appliance can be direct wired if the power supply is to
be concealed. Consult a qualified electrician if direct
wiring is required as it must comply with AS/NZS
5601.1 and AS/NZS 3000 and other relevant local
regulations.
Evolve 952/1253 Installation Guide: 13115-F 06-22 | 7