Novo Freestanding flueing options

Minimum flue length
This is required to ensure adequate draw and
to prevent spill-back of combustion products,
which can cause the safety sensors to shut
down the fire.
Min. vertical length: 3 m
Min. flue length before any bends or offsets:
900 mm (or one length of flue)
Min. 25 mm
clearance for
ceiling plate to
clear wall, may
need more to
clear scotia
Freestanding straight
vertical
For this option we have a
standard single storey vertical
flue kit 3.6 m, refer p. 31. If
flueing is longer individual
flue components can be
purchased.
Visible flue sections are
powder coated in galaxy
black.
Maximum flue length
The maximum flue length is determined by
what the product has been tested, verified, and
certified to.
Max. flue length: 8 m
Max. number of bends: 2 x 45°, or 2 x 90°
Max. 2m
Freestanding vertical offset
This option uses 45° bends to
offset obstructions in the roof
space.
Individual flue components
need to be purchased for this
option.
Max. 1 m
Freestanding vertical with a
90° offset wall penetration
For instances where there
may be another room above
or vertical obstructions. There
is also an option to penetrate
the wall with 45° bends.
Individual flue components
need to be purchased for this
option.
Novo freestanding installation guide: 13992-A 01-22 | 29