Gas And Electrical Supply - Rinnai Ember 600 Installation Manual

Ember series gas fireplaces
Hide thumbs Also See for Ember 600:
Table of Contents

Advertisement

Gas supply
Gas pipe sizing must consider the gas input to this appliance, as well as other gas appliances in
the premises. The gas supply termination is inside the heater, and enters from the lower right hand
side of the appliance.
approx. 320 mm
Electrical supply
The Ember is fitted with a 1.5 m power cord and 3-pin plug.
The power cord passes through a slot in the back left hand
corner of the appliance.
The connection is either direct wired* or connected to a
power point within the cavity. This must be connected to a
dedicated earthed power point. The electric isolation switch
must be accessible after the appliance has been installed.
The fire must not be located immediately below a socket
outlet (potential fire hazard).
If the supply cord is damaged, it must be replaced by a licensed tradesperson. This must be a
genuine replacement part available from Rinnai.
* Consult a qualified electrician if direct wiring is required as it must comply with AS/NZS 5601 and AS/NZS 3000 and other relevant
local regulations
8 | Ember Installation Guide: 12890-F 06-21
Purging the gas supply
Foreign materials and debris such as swarf,
filings etc. must be purged from the gas supply.
Failure to do so may cause damage to the
control valve causing it to malfunction.
Gas connection
A small spanner has been provided, located in
the commissioning pouch on top of the PCB
cover, to help with the gas connection as space
is quite tight. Please return the spanner to the
pouch when finished.
The use of a rubber hose for any gas
connection to a fixed appliance is not
authorised by the manufacturer.