Gas Supply; Electrical Supply - Rinnai RDV3611ETRN Installation Manual

Hide thumbs Also See for RDV3611ETRN:
Table of Contents

Advertisement

Gas supply

Gas pipe sizing must consider gas input to this appliance as well as other gas appliances in the
premises.
The gas connection from the control valve is a ½ " BSP
male flare fitting. This connects straight into the gas
control on the lower left hand side of the appliance.
Refer to the dimension diagram for the gas connection
dimensions from the back and centreline of the unit.
To access the gas connection, remove the upper and
lower bracket (also called the service access panels).
The brackets can be removed by undoing the screws as
shown below at each end of the unit.

Electrical supply

The Symmetry is fitted with a 1.5 m power cord and a 3-pin plug.
The standard electrical connection is to the right side of the front of
the appliance. If necessary this can be changed by an electrician to
terminate on the left.
The connection is either direct wired* or connected to a power point
within the cavity. This must be connected to a dedicated 230 V, 10 A
earthed power point. The electric isolation switch must be accessible
after the appliance has been installed.
The unit must not be located below a power socket outlet (potential fire
hazard).
If the supply cord is damaged, it must be replaced by a licensed tradesperson. This must be a
genuine replacement part available from Rinnai.
* Consult a qualified electrician if direct wiring is required as it must comply with AS/NZS 5601.1 and AS/NZS 3000 and
other relevant local regulations.
Connection access
Symmetry RDV3611 installation guide 11156-H 08-21 | 5
Flared union
Gas control

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdv3611etrl

Table of Contents