Supply Connections; Gas Supply; Electrical Supply - Rinnai RHFE 952 ETRN Operation & Installation Manual

Table of Contents

Advertisement

GAS SUPPLY

Gas pipe sizing MUST consider the gas input to this appliance as well as all other gas appliances
in the premises. The gas meter and regulator MUST be specified for the total gas rate.
WARNING
A suitable sizing chart such as the one in AS/NZS 5601 should be used.
The use of rubber hose for any gas connection to a fixed appliance is NOT authorised by the
manufacturer.
Confirm correct gas type (see labels located on top or rear panels). Refer to local gas authority
for confirmation of gas type if you are in doubt.
IMPORTANT
Installation of Consumer Piping
The gas supply (consumer piping),
termination is inside the heater and
enters from the lower left hand side of
the appliance when viewed from the
front.
Purging Gas Supply
Foreign materials and debris such as
swarf, filings, etc. MUST be purged/
removed from the gas supply, failure
to do so may cause damage to the gas
control valve causing it to malfunction.
Use a soapy solution to leak test all gas connections. If a leak is present bubbles will form.
When finished remove residue with a rag. Prevent soapy solution from contacting electrical
components.
CAUTION

ELECTRICAL SUPPLY

Socket Outlet
Where a power point is used it MUST be 230 V, rated at 10A and MUST
be earthed. This power point MUST NOT be located above the heater.
Alternatively the appliance can be direct wired if the power supply is to be
concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
which exits the appliance from the rear panel at the lower right when
viewed from the rear.
Direct Wired Installations
Alternatively the appliance can be direct wired if so required.
A qualified electrician will need to be consulted where a direct wired installation is required.
Any such installation MUST comply with the requirements of AS/NZS 5601, AS/NZS 3000 and
IMPORTANT
any other relevant local regulations.