Electrical supply

This heater has a 1.5 m power cord with a three pin plug supplied.
The power cord passes through a slot in the front right hand side of
the appliance, approximately 140 mm from the front of the unit.
Rinnai recommend the heater be plugged into a 230 V, 10 A
earthed power point. The power point must not be above the heater.
Alternatively the appliance can be direct wired if the power supply is to
be concealed. Consult a qualified electrician if direct wiring is required
as it must comply with AS/NZS 5601.1 and AS/NZS 3000 and other
relevant local regulations

Flue terminal position

The below diagram highlights the position of the flue terminal in relation to the glass centreline
Glass centreline
Linear 800
Linear 1000
655 mm
755 mm
A
800 mm
575 mm
B
Linear installation guide 13563-B 02-19 | 17
approx.
140 mm
Linear 1500
1005 mm
575 mm