SUPPLY CONNECTIONS
ELECTRICAL SUPPLY
Socket Outlet
Where a power point is used it MUST be 230 V, rated at 10A and MUST be
earthed. This power point MUST NOT be located above the heater. Alternatively
the appliance can be direct wired if the power supply is to be concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
exits the appliance from the rear panel at the lower right when viewed from the
rear.
Direct Wired Installations
Alternatively the appliance can be direct wired if so required.
A qualified electrician will need to be consulted where a direct
wired installation is required.
IMPORTANT
Any such installation MUST comply with the requirements
of AS/NZS 5601, AS/NZS 3000 and any other relevant local
regulations.
Using an existing externally mounted power point
If you already have an existing power point outside the enclosure, you can redirect the power cord through the LHS
or RHS of the front panel. With the frame removed redirect the cord and plug (with the grommet), underneath the
unit and to the front (left or right).
Remove the pre-punched metal knock-out
grommet is fitted to the metal knock-out. Excess cord may be left in the cavity below the unit—DO NOT coil
excess cord.