Material Selection - Rinnai Novo Cube Installation Manual

Table of Contents

Advertisement

Material selection

The temperature in front of the fire (approximately 200-350 mm x 400 mm wide) can reach up to
40 °C above ambient, which is why material selection is important. For example, vinyl planks are
a popular option for flooring, however vinyl is only rated for ambient temperatures. In this example
it would not be recommended that the fire is installed directly on the floor unless there was some
form of floor protection in front of the fire.
Some material selection guidelines, depending on the material rating, are shown below.
C
D
E
Dim. Description
A
Overhang
B
Clearance above
C
Side overhang
D
Side clearance
E
In front
F
Clearance to floor
G
Hearth depth
H
Directly on floor
I
Flue clearance
The shaded cells denote measurements A, B, C, and D. These figures are dependent on each other and the
type of installation. There is some wiggle room to these dimensions if they follow some specific calculations.
These calculations are based on figures obtained during in-house temperature testing. For more information
refer to the next page, and page 34.
Just because a material is rated to higher than 60 °C does not mean it will not deteriorate when exposed to heat
cycles. Always refer to the material supplier for suitability. The temperatures given are assuming the fire is operating
in a room temperature of no more than 25 °C. Operation in higher ambient temperatures may result in higher surface
temperatures. Non-combustible materials should be made of heat resistant material.
8 | Novo freestanding installation guide:13992-A 01-22
I
A
B
F
F
Non-combustible
hearth
Non-combustible materials
or materials rated 60 °C or
higher
No restriction as long as
materials within 400 mm to
the side (D) are of the same
rating
50 mm min.
No restrictions
50 mm min.
No restrictions
No restrictions
No restrictions
No restrictions
25 mm min.
50 mm min
G
Material temperature rated above ambient
Materials rated to a
maximum of 50 °C
Not suitable if B is under 250 mm
No restrictions if B is greater than 1000 mm
If B is 300-1000, refer p.34
100 mm min.
No restrictions if D is greater than 400 mm
50 mm min.
150 mm max.
150 mm min.
400 mm min. of non-
combustible material
Not suitable for heat sensitive materials
50 mm min.
A
B
Side view
H
Unrated materials, anything
up to a maximum of 20 °C
200 mm min
100 mm min.
100 mm max.
240 mm min.
450 mm min. of non-
combustible material

Advertisement

Table of Contents
loading

This manual is also suitable for:

Novo freestanderRdv2320fnRdv2320fl

Table of Contents