Novo freestanding flueing overview
General installation information
The flue is built from the bottom up. The galaxy black sections of the flue are supported by the fire in the event of the fire needing to
be removed for maintenance, servicing etc. The pipes are interlocking. Use of sealant is optional.
Suitable flashing (not provided)
3
30 | Novo freestanding installation guide:13992-A 01-22
1.
Novo freestanding vertical
2
2.
Novo freestanding vertical offset
3.
Novo freestanding vertical wall penetration
1
For all flue options ensure a minimum clearance of 500 mm from the roof
to the underside of the flue cowl, as per 5601.1 6.9.2
25 mm clearance
Galaxy black ceiling plate (not shown)
Galaxy black 90° bend
Visible sections of the flue are painted black
50 mm minimum rear clearance for the ceiling plate to clear the wall—additional
clearance may be required to clear scotia