Electrical supply

This heater has a 1.5 m power cord with a three pin plug supplied.
The power cord passes through a slot in the front right hand side of
the appliance, approximately 140 mm from the front of the unit.
Rinnai recommend the heater be plugged into a 230 V, 10 A
earthed power point. The power point must not be above the heater.
Alternatively the appliance can be direct wired if the power supply is to
be concealed. Consult a qualified electrician if direct wiring is required
as it must comply with AS/NZS 5601.1 and AS/NZS 3000 and other
relevant local regulations

Flue terminal position

The below diagram highlights the position of the flue terminal in relation to the glass centreline.
Glass centreline
18 | Linear installation guide 13563-H 08-19
Linear 800
Linear 1000
A
655 mm
755 mm
B
800 mm
575 mm
approx.
140 mm
Linear 1500
1005 mm
575 mm