Electrical Supply - Rinnai SS850 Installation Manual

Hide thumbs Also See for SS850:
Table of Contents

Advertisement

ELECTRICAL SUPPLY

Socket Outlet
Where a power point is used it MUST be 230 V, rated at 10A and MUST
be earthed. This power point MUST NOT be located above the heater.
Alternatively the appliance can be direct wired if the power supply is to be
concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
which exits the appliance from the rear panel at the lower right when
viewed from the rear.
Direct Wired Installations
Alternatively the appliance can be direct wired with an isolation switch if so
required.
A qualified electrician will need to be consulted where a direct wired installation is required.
Any such installation MUST comply with the requirements of AS/NZS 5601, AS/NZS 3000 and
IMPORTANT
any other relevant local regulations.
The power cord is not fire rated and MUST NOT come into contact with the unit. If the power
cord is damaged, it MUST be replaced by a licensed tradesperson. This must be a genuine
replacement part available from Rinnai.
WARNING
Rinnai
9
13
SUPPLY CONNECTIONS
SS850 Freestanding IM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ss850fcanSs850fcal

Table of Contents