SECTION 4 |
4.8.2.4.1 Programming Steps for Parameter "REMOTE SWITCH"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
4.8.2.5 RELAY FUNCTION (Table 4.9, Screen No. 5 under Column 2)
i
INFO
Menu "RELAY FUNCTION" will be displayed only for Models (i) EVO-2212 / 3012 / 2224 / 4024, (ii) EVO-
2212E / 3012E / 2224E / 4024E and (iii) EVO-4248SP. It will not be displayed for Models EVO-1212F / 1212F-
HW / 1224F / 1224F-HW.
A Single Pole Double Throw (SPDT) Status Relay with 3 contacts (Contact Rating: 3A ; 125 VAC / 30 VDC) has been
provided in Model Nos. EVO-2212 / 2212E / 3012 / 3012E / 2224 / 2224E / 4024 / 4024E / 4248SP that can be
used for (i) signaling of operational status [Options 0 and 1 - See Section 4.8.2.5.1] and (ii) providing contact closure
/ opening for automatic starting and stopping of generator through appropriate optional Generator Auto Start /
Stop Control Module (Options 2, 3 and 4 - See Sections 4.8.2.5.2.1 to 4.8.2.5.2.3). The 3 contacts of the Status
Relay are connected to 3 terminals of Terminal Block marked "Status Relay"(14, Fig 2.1 in the Owner's Manual for
the Inverter / Charger) on the front panel. The contacts are marked "NO" (Normally Open), "Common" and "NC"
(Normally Closed). When the Status Relay is OFF (de-energized), contacts marked "Common" and "NO" will be in
open condition and contacts marked "Common" and "NC" will be in closed condition. When the Status Relay is ON
(energized), contacts marked "Common" and "NO" will close and contacts marked "Common" and "NC" will open.
Diagram showing steps for programming the parameter RELAY FUNCTION (Table 4.8, Screen No.5 under Column 2)
and details of 5 different associated Options 0 to 4 are provided in the succeeding paragraphs.
4.8.2.5.1 Signaling of Operational States (Options 0 and 1)
NOTE: Applicable ONLY for Models (i) EVO-2212 / 3012 / 2224 / 4024, (ii) EVO-2212E / 3012E / 2224E / 4024E and
(iii) EVO-4248SP.
a) Option "0 = Charger/Other": When EVO™ Inverter/Charger Model (i) EVO-2212/3012/2224/4024 or, (ii)
EVO-2212E/3012E/2224E/4024E or, (iii) EVO-4248SP is in "Charging" Mode, the Status Relay will be OFF (de-
energized) [(i) "Common" and "NO" contacts will be in open condition and (ii) "Common" and "NC" contacts
will be in closed condition]. In "Other" operating modes i.e. in "Inverting", "Power Save" or in "Standby"
Modes, the Status Relay will be ON (energized) [(i) Common and "NO" contacts will close and (ii) "Common"
and "NC" contacts will open].
Parameter Setup
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
R E M O T E
S
W
I T C H
0 = B u t t o n
Down Key x 4 times
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
Enter Key
P a s s w o r d
k e y
0 0 0 0
ð
Password 8052
See Section 4.3.1
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
ð
*
P O
E R
S A V I N G
W
0 = D i s a b l e
Enter Key
S e l e c t
P a r a m e t e r
i n
O T H E R
F U N C T I O N
ð
*
R E M O T E
S
0 = B u t t o n
See Table 4.9, Parameter Setup
Screen No. 4
for programmable options
SAMLEX AMERICA INC. | 99