SECTION 4 |
TABLE 4.5
PARAMETER "CHARGING PROFILE" - OPTIONS FOR 3-STAGE / 2-STAGE CHARGING
Options under
Srl
Programming Parameter
No.
"CHARGING PROFILE"
1
0 = 3 Stage Adaptive
(Shown as "0=3 Stg
Adaptive" in the
programming screen)
NOTES:
1. This is the default setting
2. This is a 3-Stage, Adaptive
Profile with "Adaptive
Time Algorithm" for the
Absorption Stage (For
details, refer to Section
5.7.2 of the attached
Owner's Manual for
EVO-1212F/1212F-
HW/1224F/1224F-HW)
2
1=3Stage Type1
Parameter Setup
1. Stage 1 – Bulk Stage (For details, see Section 5.7.1.1 of the Owner's Manuals for
EVO
Series Inverter/Chargers):
TM
Charge at constant current = the programmed value of parameter "BULK
CURRENT"
(For details of programming range & procedure, refer to Section 4.4.2.1)
Transition to Absorption Stage when voltage rises to the set value for programming
parameter "ABSORP VOLTAGE"
4.4.2.2)
2. Stage 2 - Absorption Stage (For details, see Section 5.7.2 of the Owner's Manuals
for EVO
Series Inverter/Chargers):
TM
Charge at constant voltage = the programmed value for parameter "ABSORP
VOLTAGE".
(For details of programming range & procedure, refer to Section 4.4.2.2)
Adaptive Time Algorithm: Time in Absorption Stage is computed automatically
based on time in Bulk Stage (
1212F/1212F-HW/1224F/1224F-HW).
Transition to Float Stage thereafter.
3. Stage 3 - Float Stage (For details, see Section 5.7.3 of the Owner's Manuals for EVO
Series Inverter / Chargers):
Charge at constant voltage = the programmed value for parameter "FLOAT
VOLTAGE".
(For details of programming range & procedure, refer to Section 4.4.2.4
Reset to Bulk Stage under the following conditions:
i.
If the AC input fails or is switched off and is restored subsequently.
ii. If battery voltage falls to the programmed value of parameter "RESET TO
BULK".
(For details of programming range & procedure, refer to Section 4.4.2.15).
iii. If the charger remains in the Float Stage for 10 days
1. Stage 1 – Bulk Stage (For details, see Section 5.7.1.1 of the Owner's Manuals for
EVO
Series Inverter/Chargers):
TM
Charge at constant current = the programmed value of parameter "BULK
CURRENT"
(For details of programming range & procedure, refer to Section 4.4.2.1)
Transition to Absorption Stage when voltage rises to the set value for programming
parameter "ABSORP VOLTAGE"
4.4.2.2)
2. Stage 2 - Absorption Stage (For details, see Section 5.7.2 of the Owner's Manuals
for EVO
Series Inverter / Chargers):
TM
Charge at constant voltage (CV) = the programmed value for parameter "ABSORP
VOLTAGE".
(For details of programming range & procedure, refer to Section 4.4.2.2)
Remain in Absorption Stage for time duration = programmed value of parameter
"ABSORP TIME"
(For details of programming range & procedure, refer to Section 4.4.2.19)
Transition to Float Stage thereafter.
3. Stage 3 - Float Stage (For details, see Section 5.7.3 of the Owner's Manuals for EVO
Series Inverter / Chargers):
Charge at constant voltage = the programmed value of parameter "FLOAT
VOLTAGE".
(For details of programming range & procedure, refer to Section 4.4.2.4 )
Reset to Bulk Stage under the following conditions:
i.
If the AC input fails or is switched off and is restored subsequently.
ii. If battery voltage falls to the programmed value of parameter "RESET TO
BULK".
(For details of programming range & procedure, refer to Section 4.4.2.15).
iii. If the charger remains in the Float Stage for 10 days
Charging Stages
(For details of programming range & procedure, refer to Section
For details, refer to Section 5.7.2 of the Owner's Manual for EVO-
(For details of programming range & procedure, refer to Section
Battery Type
− Lead Acid: Flooded
and sealed – AGM/
Gel Cell
− ENSURE that there are
no other DC load(s)
on the batteries.
Load(s) on the battery
may drain full or
part of the charging
current and will
upset the "Adaptive
Time Algorithm" for
Absorption Stage time
TM
)
− Lead Acid: Flooded
and sealed – AGM/
Gel Cell
− Lithium (For details,
see Section 5.11 of
Owner's Manuals for
EVO
Series Inverter/
TM
Chargers)
TM
SAMLEX AMERICA INC. | 69

Advertisement

Table of Contents
loading

Table of Contents