SamplexPower EVO-RC-PLUS Owner's Manual page 11

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 3 |
3.3 DATE AND TIME SETUP
Set date and time as per procedure given at Section 4.10: "Group 7 Parameter Setup: Time Setting".
3.4 STANDBY MODE
When the EVO™ is in Standby Mode, inverting or charging / AC pass through will be suspended.
i
INFO
Standby Mode may be used to temporary halt normal operation of the Inverter/Charger without switching OFF
the unit completely.
For the Standby Mode to be switched ON, the EVO™ should be in ON condition, and displaying one of the active
Operating Mode screens from the associated Menu Maps detailed in Table 3.1 under Section 3.6.1. When Standby
Mode is switched ON, the EVO™ will suspend its Operating Mode.
Standby Mode is toggled between ON and OFF conditions as detailed at Section 3.4.1.
3.4.1 Procedure to Enter and Exit Standby Mode / Status Display in Standby Mode
i
INFO
EVO-RC-PLUS Remote Control will be required to be connected to the EVO
enter Standby Mode as explained at Section 3.4.1.1 below. Once Standby Mode has been entered using
EVO-RC-PLUS Remote Control, it can ALSO be switched off using the On/Off Push Button on the front
panel of the EVO
If EVO-RC-PLUS Remote Control has NOT been connected to the EVO
Mode cannot be entered using the On/Off Push Button on the front panel of the EVO
Unit
3.4.1.1 Entering Standby Mode Using Remote Control EVO-RC-PLUS: Changing over from any
Operating Mode ("Inverting", "Charging", "Power Save" etc.) to Standby Mode can be carried out with the
help of Remote-Control EVO-RC-PLUS as follows:
a) From any Operating Mode Screen ("Inverting", "Charging", "Power Save" etc.), press the On/Off Key (2, Fig
1.1) momentarily (0.1 sec)
b) Screen shown below will be displayed for 5 sec and then, the screen will go back to the Operating Mode
Screen.
G o
t o
S t a n d b y
Y e s
=
O n / O f f
N o
=
B a c k
• If Standby Mode is required to be activated, press the On/Off Key (2, Fig 1.1) momentarily (0.1 sec)
• If Standby Mode is not required to be activated, press the Back Key (5, Fig 1.1) momentarily (0.1 sec)
c) On entering Standby Mode, the following will be displayed:
Operation
Inverter/Charger Unit (See Section 3.4.1.2)
TM
?
k e y
k e y
Inverter/Charger Unit to
TM
Inverter/Charger Unit, Standby
TM
Inverter/Charger
TM
SAMLEX AMERICA INC. | 11