SamplexPower EVO-RC-PLUS Owner's Manual page 62

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 4 |
4.4.2.12.1 Programming Steps for Parameter "EQUALIZE-4STAGES"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
4.4.2.13 MODE (Table 4.3, Screen No. 13)
Under Parameter "MODE" Menu, the following 3 options can be programmed:
• Option "0=Normal" (Also called "Offline Mode" with Grid/ Generator priority. This is the Default option)
• Option "1=Online" (Also called "Online Mode" with Inverter priority)
• Option "2=Charger Only" (explained further at Section 4.4.2.13.1)
For more information on the applications of parameter "MODE" and its 3 options, please refer to the following sections:
Section 4.6.5 of Owners Manual for Models EVO-1212F / 1212F-HW / 1224F / 1224F-HW
Section 4.8.5 of Owners Manual for Models (i) EVO-2212 / 3012 / 2224 / 4024 and (ii) EVO-2212E / 3012E /
2224E / 4024E
Section 4.6.5.of Owners Manual for Models EVO-4248SP
4.4.2.13.1 Charger Only Mode (Table 4.3, Screen No. 13)
Under Parameter "MODE" (Section 4.4.2.13), 3 options can be programmed: "0=Normal" (Off-line Mode) or,
"1=Online" or, "2=Charger Only".
When "Charger Only" Mode is selected (Option "2=Charger Only"), EVO™ will charge the batteries and pass through
the AC input power to the loads as long as AC input is available.
Charging Mode Screens will be displayed as follows:
For EVO-1212F / 1212F-HW / 1224F / 1224F-HW: Menu Map at Fig 3.3(a)
o
For EVO-2212 / 2212E / 3012 / 3012E / 2224 / 2224E / 4024 / 4024E: Menu Map at Fig 3.3(b)
o
For EVO-4248SP: Menu Map at Fig 3.3(c)
o
Extract of Screen No.1 for EVO-1212F is shown below as an example.
E V O - 1 2 1 2 F
C h a r g i n g
0 - B u l k
S t a g e
B a t t :
1 2 . 0 0 V
1 0 0 . 0 A
E x t e r n a l :
When the AC input fails, the Inverter Section will NOT be activated and the AC side loads will lose AC power. The
EVO™ will internally operate in Standby Mode as long as AC input power is NOT available.
62 | SAMLEX AMERICA INC.
Parameter Setup
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
P a s s w o r d
k e y
0 0 0 0
Password 8052
See Section 4.3.1
0 . 0 A
Enter Key
S e l e c t
P a r a m e t e r
C H A R G E
ð
*
B U L K
C U R R E N T
2 0 A
Enter Key
S e l e c t
P a r a m e t e r
i n
C H A R G E
ð
*
E Q U A L I Z E - 4 S T A G E S
0 = N o
See Table 4.3, Parameter Setup
Screen No. 12 for
programmable options
Down Key x 11 times
S e l e c t
C U R V E
C H A R G E
ð
*
E Q U A L I Z E - 4 S T A G E S
C U R V E
Enter Key
P a r a m e t e r
C U R V E
ð
0 = N o