SECTION 4 |
4.3.1 Example of Password Activation and Changing Bulk Current Setting for EVO-1212F / 1212F-
HW from Default Value of 20A to 50A
S e l e c t
G r o u p
*
C H A R G E
C U R V E
S e l e c t
G r o u p
*
C H A R G E
C U R V E
B U L K
C U R R E N T
2 0 A
P a s w o r d
k e y
i n
0 0 0 0
P a s w o r d
c o r r e c t
P a s w o r d
e r r o r ! !
Parameter Setup
Starting from any of the 5 Operating Mode Screens (shown at Figs
3.1 to 3.8), press Enter Key. Screen "Select Group, CHARGE CURVE"
as shown on the left will be displayed (Parameter Group 1 of "Select
Group" Menu Map, Fig 4.1)
Press Enter key to access 24 Parameter Screens under "Select
Parameter" Menu Map for Parameter Group 1 "Charge Curve" (Fig
4.2) [Parameters are detailed at Table 4.3 under Section 4.4.1].
Screen "BULK CURRENT, 20A" as shown on the left will be displayed
(Screen No.1 of "Select Parameter" Menu Map for Parameter Group
1: CHARGE CURVE at Fig 4.2). Default current setting of 20A or
previously set value will be displayed.
Press Enter Key to change Bulk Current parameter setting. A Password
will be requested. Password will NOT be requested if disabled - see
Section 4.3.2.
Password consisting of 4 digits "0000" will be requested as shown
on the left (NOTE: Password to be entered is 8052). The first digit
will have a blinking cursor "_". Use Up /Down Keys to scroll to
number 8 for the first digit "8" of the password. Momentarily press
Enter Key (Short press). Digit 8 will be entered as the first digit of
the Password and the blinking cursor will automatically move to the
2nd digit (0) to the right. As the next digit in the Password "8052"
is already "0", momentarily press Enter Key (Short press) to enter
"0" in the second digit. The blinking cursor will automatically move
to the 3rd digit (0). Use Up /Down Keys to scroll to number 5 for the
3rd digit "5" of the password "8052" and momentarily press Enter
Key (Short press). The blinking cursor will automatically move to the
4th digit (0). Use Up /Down Keys to scroll to number 2 for the 4th
digit "2" of the password "8052". Now keep the Enter Key pressed
continuously for longer time (3 to 4 sec) to write the full password
of 4 digits i.e. "8052".
Flashes twice when Password is correct. (8052)
Flashes twice when Password is NOT correct.
SAMLEX AMERICA INC. | 47