SamplexPower EVO-RC-PLUS Owner's Manual page 77

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 4 |
4.5 GROUP 2 PARAMETER SET UP: INPUT SETTING
4.5.1 Programming Ranges & Default Values of Programming Parameters under Parameter Group
2 – INPUT SETTING
Table 4.6 gives details of programming ranges & default values of parameters under Parameter Group No.2 - "INPUT SETTING" .
Refer to Fig 4.3 under Section 4.1.3.2 for Menu Map for navigating through various parameters under this Group No.2.
TABLE 4.6 Programming Information for Parameter Group No.2 - INPUT SETTING
(Refer to Menu Map at Fig 4.3, Section 4.1.3.2)
Parameter
Parameter
Setup
Setup
Screen
Screen
Nos. for:
Nos. for:
-
EVO
EVO-
1212F
2212/ 2212E
1212F-HW
3012/ 3012E
Parameter
1224F
2224/ 2224E
1224F-HW
4024/ 4024E
4248SP
(Column 1)
(Column 2)
1
1
DEFAULT FREQ
GRID MAX
2
2
CURRENT
-
3
GEN MAX CURRENT
(See NOTE 2)
3
4
HIGH CUT OFF
4
5
HIGH RESET
5
6
LOW CUT OFF
6
7
LOW RESET
7
SYNCHRONIZATION
(See NOTE 3)
8
SYNC GRID
(See NOTE 4)
9
SYNC GEN
(See NOTE 4)
8
10
INPUT OC PROTECT
9
11
INPUT RECOVERY
Parameter Setup
EVO-1212F
EVO-
/1212F-HW
2212
(Column
(Column
(Column 3)
4)
See NOTE 1
0=60Hz;
0=60Hz; 1=50Hz
(Default:
(Default: 0=60Hz)
60Hz)
5 – 20A
5 – 40A
(Default:
(Default:
20A)
30A)
5 – 40A
(Default:
30A)
0=Fine
(Default)
1=Coarse
0=Fine (Default)
1=Coarse (Default)
Setting range
EVO-
EVO-1224F
EVO-
3012
/1224F-HW
2224
(Column
(Column
(Column
5)
6)
7)
8)
See NOTE 1
0=60Hz;
(Default:
0=60Hz)
5 – 70A
5 – 20A
5 – 40A
(Default:
(Default:
(Default:
30A)
20A)
30A)
5 – 70A
5 – 40A
(Default:
(Default:
30A)
30A)
50 – 70Hz
(Default: 65Hz)
50 – 70Hz
(Default: 64Hz)
40 – 60Hz
(Default: 55Hz)
40 – 60Hz
(56Hz)
0=Fine
(Default)
1=Coarse
0=Fine (Default)
1=Coarse
0=Fine
0=INV mode (Default)
0=Buffered (Default)
EVO-
EVO-
EVO-
4024
4248SP
2212E
(Column
(Column
(Column
9)
10)
11)
0=60Hz; 1=50Hz
(Default: 0=60Hz)
5 – 70A
5 – 30A
5 – 20A
(Default:
(Default:
(Default:
30A)
30A)
16A)
5 – 20A
5 – 70A
(Default:
(Default:
16A)
30A)
0=Fine
(Default)
1=Coarse
1=Coarse
1=Coarse
(Default)
0=Fine
1=Shutdown
1=Direct
SAMLEX AMERICA INC. | 77
EVO-
EVO-
EVO-
3012E
2224E
4024E
(Column
(Column
(Column
12)
13)
14)
0=50Hz; 1=60Hz
(Default: 0=50Hz)
5 – 25A
5 – 20A
5 – 35A
(Default:
(Default:
(Default:
16A)
16A)
16A)
5 – 25A
5 – 20A
5 – 35A
(Default:
(Default:
(Default:
16A)
16A)
16A)
50 – 70Hz
(Default: 55Hz)
50 – 70Hz
(Default: 54Hz)
40 – 60Hz
(Default: 45Hz)
40 – 60Hz
(Default: 46Hz)
0=Fine (Default)
1=Coarse
1=Coarse (Default)
0=Fine

Advertisement

Table of Contents
loading

Table of Contents