SamplexPower EVO-RC-PLUS Owner's Manual page 4

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 1 |
RJ-45
Pin #
Signal
1
12V
2
12V
3
ON/OFF
4
D+
5
D-
6
NC
7
GND
8
GND
Pin Out of Plug - End 1
1.3 PINOUT DIAGRAMS & INTERNAL INTERCONNECTION OF RJ-45 & RJ-12 JACKS
RJ-45 Jack (10, Fig 1.1) and RJ-12 Jack (11, Fig 1.1) are internally connected as pinout at Fig 1.3.
4 | SAMLEX AMERICA INC.
Introduction and Layout
Straight
RJ-45
Connection
Pin #
Pin Out of Plug - End 2
Fig 1.2 Pin Out of Plugs for 8P8C, RJ-45 Connecting Cable
RJ-12
Pin #
Signal
6
ON/OFF
5
12V
4
D+
3
D-
2
GND
1
NC
123456
1 2 3 4 5 6 7 8
RJ-12 (6P6C) Jack
Fig 1.3 Pinout and internal interconnections of RJ-45 (8P8C)
and RJ-12 (6P6C) Jacks on EVO-RC-PLUS
Top view of Plug -
Locking Tab facing down
Signal
1
12V
2
12V
3
ON/OFF
4
D+
5
D-
6
NC
7
GND
8
GND
RJ-45 (8P8C) Jack
Front view of Plug -
8P 8C, RJ-45 Modular Plug
RJ-45
Pin #
Signal
1
12V
2
12V
3
ON/OFF
4
D+
5
D-
6
NC
7
GND
8
GND
123456
1 2 3 4 5 6 7 8
Locking Tab
facing up

Advertisement

Table of Contents
loading

Table of Contents