SECTION 4 |
TABLE 4.4
CHARGING PROFILE FOR 4-STAGE ADAPTIVE CHARGING FOR EQUALIZATION
Options under
Srl
Programming
No.
Parameter
"EQUALIZE–4 STAGES"
1
EQUALIZE – 4 STAGES
0 = No (Default Setting)
1 = Yes
i
INFO
For complete understanding of the above 4 Stages of Charging and the associated Charging
Curves, please refer to Sections 5.8 and 5.9 of the following Owner's Manuals:
(i) Owner's Manual for EVO-1212F / 1212F-HW / 1224F / 1224F-HW
(ii) Owner's Manual for EVO-2212 / 3012 / 2224 / 4024
(iv) Owner's Manual for EVO-2212E / 3012E / 2224E / 4024E
(iv) Owner's Manual for EVO-4248SP
Parameter Setup
Charging Stages
1. Stage 1 – Bulk Stage
Charge at constant current (CC) = the programmed value
of parameter "BULK CURRENT"
procedure, refer to Section 4.4.2.1
Transition to Absorption Stage when voltage rises to the
set value for programming parameter "ABSORP VOLTAGE"
For details of programming range & procedure, refer to Section 4.4.2.2
2. Stage 2 - Absorption Stage
Charge at constant voltage (CV) = the programmed value
for parameter "ABSORP VOLTAGE".
range & procedure, refer to Section 4.4.2.2
Adaptive Time Algorithm: Time in Absorption Stage is
computed automatically based on time in Bulk Stage
Transition to Equalization Stage thereafter.
3. Stage 3 - Equalization Stage
Charge at constant voltage (CV) = the programmed value of
parameter "EQUALIZE VOLTAGE".
& procedure, refer to Section 4.4.2.3.
Adaptive Time Algorithm: Time in Equalization Stage is
computed automatically based on time in Bulk Stage.
Transition to Float Stage thereafter.
4. Stage 4 -
This stage will be the same as the last Stage of Charging Profile
from where Equalization was started.
Battery Type / CAUTIONS!
− Lead Acid: Flooded only
For details of programming range &
For details of programming
For details of programming range
!
CAUTIONS!
1. Equalize Flooded Lead Acid Batteries only.
Sealed AGM / Gel Cell types of batteries are
NOT equalized
2. Refer to Section 5.8.2 and Fig 5.2 of the
Owner's Manuals for EVO
TM
Chargers Series
3. The Adaptive Charging Algorithm measures
the Bulk Stage Time (T0) to automatically
compute Absorption Stage Time (T1') and
Equalization Stage Time (T2). This algorithm
is fully effective only when there are no
other external DC loads being supplied by
the battery that may divert full or part of
the BULK CURRENT resulting in undesired
increase in Bulk Stage Time "(T0)" and
consequently, undesired increase of
Absorption Stage Time (T1') and Equalization
Stage Time (T2). Hence, disconnect all other
external DC loads on the battery during the
equalization cycle.
!
ATTENTIONS!
1. Égaliser les batteries au plomb inondées
seulement. Les batteries scellées de type
AGM / cellules au gel ne sont pas égalisées.
2. Se reporter à la section 5.8.2 et figure 5.2
du manuels pour onduleurs / chargeurs de
la série EVO.
3. L'algorithme de charge adaptative l'essentiel
des mesures de phase (T0) pour calculer
automatiquement l'étape d'Absorption
Temps (T1') et de la péréquation, le temps
(T2). Cet algorithme n'est pleinement
efficace que lorsqu'il n'y a pas d'autres
charges c.c. externe alimenté par la
batterie qui peut détourner tout ou
partie de l'ACTUEL EN VRAC résultant
en une augmentation indésirable en vrac
temps Étape "(T0)" et par conséquent,
augmentation indésirable de l'étape
d'Absorption Temps (T1') et de la
péréquation le temps (T2). Par conséquent,
déconnectez toutes les autres charges CC
externes sur la batterie pendant le cycle
d'égalisation.