SamplexPower EVO-RC-PLUS Owner's Manual page 113

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 5 |
"DATA LOGGING" Fields for model EVO-4248SP are shown in Fig 5.3 below:
Date
Time
External
Amp
Battery (c) Transformer (c) Heat
The Data Logging Fields in Figs 5.1 to 5.3 above show the average value over one of the 6 time interval options shown
below under programming parameter "DATALOG TIME" (See Section 4.8.2.10). Default time interval is 1 sec (Option
"1=1 sec). Parameter "DATALOG TIME" is also used to disable data logging (Option 0=Disable). Interval / disabling
options are shown below:
• 0=Disable ; 1=1 sec (Default) ; 2=10 sec ; 3=30 sec ; 4=60 sec ; 5=5 min ; 6=10 min
NOTE: Data Logging Fields "Error Code" and "Event" shown in Figs 5.1 to 5.3 above record "Error Code"/"Event"
as soon as they occur
5.2.3 Operating Screens when SD Card is Inserted for Data Logging
Data logging will be carried out automatically as soon as the SD Card is inserted in the SD Card Slot of EVO-RC-PLUS.
[Provided parameter "DATALOG TIME" (Section 4.8.2.10) has NOT been set to "0 = Disable")].
Operating screens are shown below:
F i l e
c r e a t i n g . . .
S D
C a r d
e r r o r !
S D
C a r d
r i t e
e r r o r !
W
S D
C a r d
f u l l !
SD Card
5.2.2.3 DATA LOGGING Fields for Model EVO-4248SP
Grid
Grid
Input
status
freq
Amp 1
Battery
Battery
Output
Amp
volt
watt 2
Heat sink
sink 1(c)
2 (c)
Fig 5.3 Data Logging Fields for EVO-4248SP
Data log function has been initiated and new file is being created. Do not remove
the SD card when file creating is displayed.
Read error, the data log function/update/upload will stop.
Write error. The Data logging function will stop.
1. Card full. Data logging function has stopped.
2. There is not enough space to create Data Log File Folder or to save file with saved
programmed parameters.
NOTE: Once there is enough space to create a Data Log File Folder and subsequently, it
runs out of capacity due to recording newer data, it will start to overwrite on older files.
Input
Input
Input
Input
Amp 2
VA 1
VA 2
watt 1
Output
Output
Output
watt 1
VA 2
VA 1
Fan
Error
Charge
speed Mode
code
stage
Input
Output
watt 2
freq
Output
Output
Output
Amp 2
Amp 1
volt
CAN
CAN
AVG
Event
status
watt
watt
SAMLEX AMERICA INC. | 113