b) Wiring Connection: Output from the Solid-State Relay (SSR) Terminals on the Lithium Battery BMS should
be wired to the RJ-45 Jack marked "Battery Temp. Sensor" (6, Fig 2.1 in the Owner's Manuals for EVO
Series Inverter/Chargers) as follows:
Connect terminal marked "+" on the SSR (Drain of Mosfet switch inside SSR) to any of pins 1/2/3/4 of
RJ-45 Jack (Pinout shown below)
Connect terminal marked "-" on the SSR (Source of Mosfet switch inside SSR) to any of pins 5/6/7/8 of
RJ-45 Jack (Pinout shown below)
Pinout of RJ-45 Jack marked "Battery Temp Sensor" on the Front Panel of EVO
When the Drain-Source terminals of the BMS close, Pins 1/2/3/4 and 5/6/7/8 of RJ-45 Jack will be shorted. The following
actions will be activated in EVO:
EVO
in Charging Mode: Charging will stop but AC input power will continue to be passed through (Internally,
TM
the EVO
will be in Charging Mode, but the charging current will be reduced to 0A). During this condition, the
TM
"Charging Mode Screens" will display message "Charger Off by BMS" as follows:
EVO-1212F / EVO-1212F-HW / EVO-1224F / EVO-1224F-HW: Fig 3.7(a), Section 3.6.8.1
(i) EVO-2212 / EVO-3012 / EVO-2224 / EVO-4024 and (ii) EVO-2212E / EVO-3012E / EVO-2224E /
EVO-4024E: Fig 3.7(b), Section 3.6.8.2
EVO-4248SP: Fig 3.7(c), Section 3.6.8.3
EVO
in Inverting Mode: Inverting will stop (Internally, the EVO
TM
condition, the "Inverting Mode Screens" will display message "Inv stop by BMS" as follows:
EVO-1212F / EVO-1212F-HW / EVO-1224F / EVO-1224F-HW: Fig 3.8(a), Section 3.6.9.1
(i) EVO-2212 / EVO-3012 / EVO-2224 / EVO-4024 and (ii) EVO-2212E / EVO-3012E / EVO-2224E /
EVO-4024E: Fig 3.8(b), Section 3.6.9.2
EVO-4248SP: Fig 3.8(c), Section 3.6.9
NOTE: Parameter "CHARGING PROFILE" will be required to be programmed to select the desired charging
profile for the Lithium Ion Battery from the following options:
1=3 Stage Type 1
2=3 Stage Type 2
3=2 Stage Type 1
4=2 Stage Type 2
5=2 Stage Type 3
Parameter Setup
(6, Fig 2.1 in the Owner's Manuals for EVO
(For details, please refer to parameter "CHARGING PROFILE" explained under
Section 4.4.2.21)
Batt Temp
1K
to DSP
+5V
5.1K
1 2 3 4 5 6 7 8
TM
will enter Standby Mode). During this
TM
Internal
Schematic
of EVO