4.5.2.3.1 Programming Steps for Parameter "GEN MAX CURRENT" (Only for EVO-2212/ 2212E / 3012 / 3012E /
2224 / 2224E / 4024 / 4024E)
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 3 0 1 2
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
1 0 . 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(b)]
4.5.2.4 HIGH CUT OFF (Table 4.6: (i) Parameter Setup Screen No.3 (Column 1) for EVO-1212F / EVO-1212F-HW /
If the AC input frequency is over the value of "HIGH CUT OFF" when in "Charging Mode", the EVO™ Inverter/
Charger will transfer to Inverting Mode.
4.5.2.4.1 Programming Steps for Parameter "HIGH CUT OFF"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
4.5.2.5 HIGH RESET (Table 4.6: (i) Parameter Setup Screen No.4 (Column 1) for EVO-1212F / EVO-1212F-HW / EVO-
1224F / EVO-1224F-HW / EVO-4248SP
(ii) Parameter Setup Screen No.5 (Column 2) for EVO-2212/ 2212E / 3012 / 3012E / 2224 /
2224E / 4024 / 4024E)
This is the reset frequency at which the unit will revert to "Charging Mode" after it has switched over to "Inverter
Mode" due to input frequency rising above "HIGH CUT OFF".
80 | SAMLEX AMERICA INC.
Parameter Setup
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
I N P U T
S E T T I N G
*
G E N
M A X
C U R R E N T
3 0 A
EVO-1224F / EVO-1224F-HW / EVO-4248SP
(ii) Parameter Setup Screen No.4 (Column 2) for EVO-2212/ 2212E / 3012 / 3012E / 2224 /
2224E / 4024 / 4024E)
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
I N P U T
S E T T I N G
*
H I G H
C U T
O F F
6 5 H z
Down Key x 1 time
S e l e c t
P a r a m e t e r
*
I N P U T
S E T T I N G
ð
Enter Key
P a s s w o r d
k e y
0 0 0 0
ð
Password 8052
See Section 4.3.1
Down Key x 1 time
S e l e c t
P a r a m e t e r
*
I N P U T
S E T T I N G
ð
Enter Key
P a s s w o r d
k e y
0 0 0 0
ð
Password 8052
See Section 4.3.1
Enter Key
S e l e c t
P a r a m e t e r
I N P U T
S E T T I N G
ð
*
D E F A U L T
F R E Q
0 = 6 0 H z
Enter Key
i n
S e l e c t
P a r a m e t e r
I N P U T
S E T T I N G
ð
*
G E N
M A X
C U R R E N T
3 0 A
See Table 4.6, Parameter Setup
Screen No. 3 (Column 2) for
programmable range for Models
EVO-2212/2212E/3012/3012E/222
4/2224E/4024/4024E
(i) Down Key x 2 times for EVO-1212F/1212F-
HW/1224F/1224F-HW/4248SP
(ii) Down Key x 3 times for EVO-2212/2212E/3012/
3012E/2224/2224E/4024/4024E
Enter Key
S e l e c t
P a r a m e t e r
I N P U T
S E T T I N G
ð
*
D E F A U L T
F R E Q
0 = 6 0 H z
Enter Key
i n
S e l e c t
P a r a m e t e r
I N P U T
S E T T I N G
ð
*
H I G H
C U T
6 5 H z
For programmable range, see Table 4.6:
(i) Parameter Setup Screen No. 3 (Column 1) for
EVO-1212F/1212F-HW/1224F/E/1224F-HW/4248SP
(ii) Parameter Setup Screen No. 4 (Column 2) for
EVO-2212/2212E/3012/3012E/2224/2224E/4024/4024E
Down Key x 2 times
ð
ð
O F F