SECTION 4 |
4.8.2.13.1 Programming Steps for Parameter "PASSWORD DISABLE"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
4.9 GROUP 6 PARAMETER SET UP: RC-PLUS SETTING
4.9.1 Programming Ranges and Default/ Factory Preset Values of Parameters Under Group 6 –
RC-PLUS SETTING
Table 4.10 below gives details of programming ranges and default values of parameters under Parameter Group 6 -
RC-PLUS SETTING. Refer to Fig 4.5 under Section 4.1.3.4 for Menu Map for navigating through various parameters
under this Group 6.
These parameters are used to control dimming of LCD back lighting of Remote Control EVO-RC-PLUS.
Table 4.10 Group 6 Parameter Set Up: RC-PLUS SETTING (Refer to Menu Map at Fig 4.5, Section 4.1.3.4)
Parameter
Parameter
Setup Screen
No.
(Column 1)
(Column 2)
1
ACTIVE LCD LIGHT
IDLE LCD LIGHT
If any key on the Remote
Control EVO-RC-PLUS has not
2
been pressed for time set by
parameter "IDLE LCD TIMER",
the backlight will dim to the
programmed option
IDLE LCD TIMER
If any key on the Remote
Control EVO-RC-PLUS has not
been pressed for time set by
3
this parameter, the backlight
will dim to the programmed
option selected through
parameter "IDLE LCD LIGHT"
Parameter Setup
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P A S S
W
O R D
D I S A B L E
0 = N o
Down Key x 4 times
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
Enter Key
P a s s w o r d
0 0 0 0
ð
Password 8052
See Section 4.3.1
(i) EVO-1212F / 1212F-HW / 1224F / 1224F-HW
(ii) EVO-2212 / 2212E / 3012 / 3012E / 2224 / 2224E / 4024 / 4024E
(iii) EVO-4248SP
0 = 0%, 1 = 25%, 2 = 50%, 3 = 75%, 4 = 100%
(Default: 4 = 100%)
0 = 0%, 1 = 25%, 2 = 50%, 3 = 75%, 4 = 100%
(Default: 1 = 25%)
(i) Down Key x 11 times for EVO-1212F/1212F-
(ii) Down Key x 12 times for EVO-2212/2212E/30
12/3012E/2224/2224E/4024/4024E
Enter Key
S e l e c t
O T H E R
ð
*
P O
0 = D i s a b l e
Enter Key
S e l e c t
k e y
i n
O T H E R
ð
*
P A S S
For programming options, see Table 4.9:
• Screen No.12 (Column 1) for
EVO-1212F/1212F-HW/1224F/1224F-HW
• Screen No.13 (Column 2) for
EVO-2212/2212E/3012/3012E/2224/2224E/
4024/4024E & EVO-4248SP
Setting range
(Column 3)
1 to 60 min.
(Default = 5 min)
SAMLEX AMERICA INC. | 107
HW/1224F/1224F-HW
& EVO-4248SP
P a r a m e t e r
F U N C T I O N
ð
E R
S A V I N G
W
P a r a m e t e r
F U N C T I O N
O R D
D I S A B L E
W
0 = N o

Advertisement

Table of Contents
loading

Table of Contents