SECTION 4 |
NOTES for Table 4.6:
1.
DEFAULT FREQ parameter is fixed al 60Hz for EVO-1212F / 1212F-HW / EVO-1224F / 1224F-HW (Option 0=60Hz). If option 1 is entered, the
screen line will show "! 1=xxHz" meaning that Option 1 is invalid.
2.
Parameter "GEN MAX CURRENT" is not available for EVO-1212F / 1212F-HW / EVO-1224F / 1224F-HW / 4248SP as separate Generator
input is not available in these models.
3.
Parameter "SYNCHRONIZATION" is not available for EVO-2212 / 3012 / 2224 / 4024 & EVO-2212E / 3012E / 2224E / 4024E
4.
Parameters "SYNC GRID" and "SYNC GEN" are not available for EVO-1212F / 1212F-HW / EVO-1224F / 1224F-HW / 4248SP
4.5.2 Description of Parameters under Parameter Group No.2 – INPUT SETTING
4.5.2.1 DEFAULT FREQ: (Table 4.6, Parameter Setup Screen No.1)
Default frequency sets the Inverter frequency, which is also the standard frequency for AC input.
4.5.2.1.1 Programming Steps for Parameter "DEFAULT FREQUENCY"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
NOTES:
1. Parameter "DEFAULT FREQ" is fixed al 60Hz for EVO-1212F / 1212F-HW / EVO-1224F / 1224F-HW (Option
0=60Hz). These units cannot be set at 50Hz (Option "1=50Hz"). If option 1 is entered for these models for 50Hz,
the screen line will show "! 1=xxHz" meaning that Option 1 is invalid.
2. For EVO-2212 / 3012 / 2224 / 4024 / 4248SP parameter "DEFAULT FREQ" can be set at 60Hz (Option
"0=60Hz" - Default) or 50Hz (Option "1=50Hz")
3. For EVO-2212E / 3012E / 2224E / 4024E parameter "DEFAULT FREQ" can be set at 50Hz (Option "0=50Hz" -
Default) or 60Hz (Option "1=60Hz")
4.5.2.2 GRID MAX CURRENT (Table 4.6, Parameter Setup Screen No. 2)
In Charging Mode, the net AC input current from the Grid is the sum of the AC side charging current and the pass
through load current. Based on the rated capacity of the Grid Branch Circuit, the net AC input current will be required
to be limited to prevent overloading of the Grid Branch Circuit.
EVO™ Series has a very powerful battery charger that will require a proportionate higher AC input current from the
Grid. The Grid Branch Circuit will also be required to provide current to the AC loads. The desired maximum value of
input current from Grid can be programmed (Default setting is (i) 20A for Models EVO-1212F / 1212F-HW / 1224F /
1224F-HW (ii) 30A for Models EVO-2212 / 3012 / 2224 / 4024 / 4248SP and (iii) 16A for Models 2212E / 3012E / 2224E
/ 4024E). The EVO™ will automatically reduce charging current to support the AC loads on priority and use whatever
is extra for charging. This will prevent overloading of the Grid Branch Circuit.
78 | SAMLEX AMERICA INC.
Parameter Setup
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
P a s s w o r d
k e y
0 0 0 0
Password 8052
See Section 4.3.1
Down Key x 1 time
S e l e c t
P a r a m e t e r
*
I N P U T
S E T T I N G
ð
Enter Key
i n
S e l e c t
P a r a m e t e r
*
I N P U T
S E T T I N G
ð
D E F A U L T
0 = 6 0 H z
See Table 4.6, Parameter Setup
Screen No. 1
for programmable options
Enter Key
S e l e c t
*
I N P U T
ð
D E F A U L T
0 = 6 0 H z
F R E Q
Enter Key
P a r a m e t e r
S E T T I N G
ð
F R E Q