SamplexPower EVO-RC-PLUS Owner's Manual page 109

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 4 |
4.9.2.3 IDLE LCD TIMER (Table 4.10, Parameter Setup Screen No.3)
During the active operation mode of the LCD display, its level of brightness is controlled by parameter "ACTIVE LCD
LIGHT" (Section 4.9.2.1). If any key on the EVO-RC-PLUS Remote Control has not been depressed for time set by this
parameter i.e. "IDLE LCD TIMER", the backlight of the LCD screen will be dimmed to the level set by parameter "IDLE
LCD LIGHT" (Section 4.9.2.2).
4.9.2.3.1 Programming Steps for Parameter "IDLE LCD TIMER"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
4.10 GROUP 7 PARAMETER SETUP: TIME SETTING
Please refer to Parameter "TIME SETTING" under Screen No. 7 for Group 7 at Fig 4.1 under Section 4.1.2. Set up details
are given below. The Date and Time Format is Year/Month/Day Hour:Minute (24 hour clock):
NOTE: Password is not required for setting this parameter.
4.10.1 Programming Steps for Parameter "TIME SETTING"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
i
INFO
• Time can be programmed from Year 2000 to 2099 only.
• Month can be programmed from 01 to 12 only.
• Day can be programmed from 01 to 31 only.
• Hour can be programmed from 00 to 24 only.
• Minute can be programmed from 00 to 60 only.
• If the numbers Entered for Month, Day, Hour and Minute are not within the above ranges,
message "OUT OF RANGE!" will be displayed and the display screen will go back to the
previously set time. Setting procedure will have to be re-started.
Parameter Setup
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
R C - P L U S
S E T T I N G
*
I D L E
L C D
T I M E R
5
m i n
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
Down Key x 5 times
S e l e c t
P a r a m e t e r
*
R C - P L U S
S E T T I N G
ð
Enter Key
P a s s w o r d
k e y
0 0 0 0
ð
Password 8052
See Section 4.3.1
Down Key x 6 times
S e l e c t
G r o u p
*
T I M E
S E T T I N G
ð
Enter Key
S e l e c t
P a r a m e t e r
R C - P L U S
ð
*
A C T I V E
L C D
4 =
1 0 0
Enter Key
S e l e c t
P a r a m e t e r
i n
R C - P L U S
ð
*
I D L E
L C D
5
See Table 4.10, Parameter Setup
Screen No.3 (Column 1)
for programmable options
Enter Key
S e l e c t
P a r a m e t e r
T I M E
S E T T I N G
ð
E n t e r
t h e
2 0 0 0 / 0 1 / 0 1
SAMLEX AMERICA INC. | 109
Down Key x 2 times
S E T T I N G
ð
L I G H T
%
S E T T I N G
T I M E R
m i n
t i m e
0 : 0 0

Advertisement

Table of Contents
loading

Table of Contents