SamplexPower EVO-RC-PLUS Owner's Manual page 97

Remote control for evolution series inverter/ charger
Table of Contents

Advertisement

SECTION 4 |
If the value of power drawn by AC load falls to the "ENTER POINT" value for 5 sec, the unit will enter "Power Save Mode".
4.8.2.2.1 Programming Steps for Parameter "ENTER POINT"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
4.8.2.3 WAKE UP POINT (Table 4.9, Parameter Setup Screen No.3)
i
INFO
For more information on use and application of Power Save Functions, please refer to the following manuals:
(i) Sections 4.6.3 and 4.6.4 in Combined Owner's Manual for EVO-1212F / 1212F-HW / 1224F / 1224F-HW
(ii) Sections 4.8.3 and 4.8.4 in Combined Owner's Manuals for (i) EVO-2212 / 3012 / 2224 / 4024 and (ii) EVO-
2212E / 3012E / 2224E / 4024E
(iii) Sections 4.8.3 and 4.8.4 in Owner's Manual for EVO-4248SP
If the unit is in "Power Save Mode" and the value of the AC power of the load rises to "WAKE UP POINT", the unit will
quit "Power Save Mode" and will start operating in full voltage "Inverting Mode".
4.8.2.3.1 Programming Steps for Parameter "WAKE UP POINT"
Any Operating Mode Screen from
Fig 3.1 to 3.8
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
[Above screen is Screen 1 of Fig 3.2(a)]
4.8.2.4 REMOTE SWITCH (Table 4.9, Parameter Setup Screen No. 4)
This selection is used when ON/OFF control of EVO™ Inverter/Charger is desired through external 12 VDC signal fed to
the terminals marked "Remote ON/OFF" on the Front Panel of EVO™ Inverter/Charger [(i)15, Fig 2.1 in the combined
Owner's Manuals for (a) EVO-2212 / 3012 / 2224 / 4024 and (b) EVO-2212E / 3012E / 2224E / 4024E, (ii) 16, Fig 2.1
in the combined Owner's Manual for EVO-1212F/1212F-HW and EVO-1224F/1224-HW and, (iii) 15, Fig 2.1 in the
Owner's Manual for EVO-4248SP].
Parameter Setup
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
E N T E R
P O I N T
6
W
Enter Key
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
A K E
U P
P O I N T
W
7
W
Down Key x 4 times
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
Enter Key
P a s s w o r d
k e y
0 0 0 0
ð
Password 8052
See Section 4.3.1
Down Key x 4 times
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
Enter Key
P a s s w o r d
k e y
0 0 0 0
ð
Password 8052
See Section 4.3.1
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
ð
*
P O
E R
S A V I N G
W
0 = D i s a b l e
Enter Key
i n
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
ð
*
E N T E R
P O I N T
6
W
See Table 4.9, Parameter Setup
Screen No. 2
for programmable range
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
ð
*
P O
W
E R
S A V I N G
0 = D i s a b l e
Enter Key
S e l e c t
P a r a m e t e r
i n
O T H E R
F U N C T I O N
ð
*
A K E
U P
W
7
W
See Table 4.9, Parameter Setup
Screen No. 3
for programmable range
SAMLEX AMERICA INC. | 97
Down Key x 1 time
ð
Down Key x 2 times
ð
P O I N T

Advertisement